Products
Types of Gas Solenoid Valve
The gas solenoid valve is the part of the interlock that actually stops the gas. Choosing the right function, voltage and size matters.
- Common sizes in stock
- Fail-safe normally closed valves
- Correctly sized for your load
Quick answer
The gas solenoid valve is the part of the interlock that actually stops the gas. Choosing the right function, voltage and size matters.
- Standards
- BS 6173, IGEM/UP/19, IGEM/UP/11
- In stock
- Interlock panels, gas solenoid valves, air pressure switches
- How to book
- Call 020 8935 5572 or book online, 24/7
Individual pages
Choose a gas solenoid valve
Select any item to see its specification, applications, installation checks and available repair service.
9 pages

Normally Closed Gas Solenoid Valve
Closes when power is lost — the fail-safe valve used on gas interlocks.
View product
Normally Open Gas Solenoid Valve
Stays open without power and closes when energised — used in specific shut-off schemes.
View product
Manual Reset Gas Solenoid Valve
Must be reset by hand after closing, so gas cannot come back on by itself.
View product
240V (230V) Gas Solenoid Valve
Mains-voltage coil — the most common coil on UK kitchen interlocks.
View product
22mm (¾") Gas Solenoid Valve
For smaller kitchens and takeaways with a modest total gas load.
View product
28mm (1") Gas Solenoid Valve
The most common commercial kitchen valve size.
View product
35mm (1¼") Gas Solenoid Valve
For larger kitchens with higher gas loads.
View product
2" (54mm) Gas Solenoid Valve
Large-bore valve for high-demand kitchens and plant rooms.
View product
Flanged Gas Solenoid Valve (DN50–DN150)
Flanged valves for large-bore commercial and industrial gas supplies.
View productGas solenoid valve types
| Type | Summary |
|---|---|
| Normally Closed Gas Solenoid Valve | Closes when power is lost — the fail-safe valve used on gas interlocks. |
| Normally Open Gas Solenoid Valve | Stays open without power and closes when energised — used in specific shut-off schemes. |
| Manual Reset Gas Solenoid Valve | Must be reset by hand after closing, so gas cannot come back on by itself. |
| 240V (230V) Gas Solenoid Valve | Mains-voltage coil — the most common coil on UK kitchen interlocks. |
| 22mm (¾") Gas Solenoid Valve | For smaller kitchens and takeaways with a modest total gas load. |
| 28mm (1") Gas Solenoid Valve | The most common commercial kitchen valve size. |
| 35mm (1¼") Gas Solenoid Valve | For larger kitchens with higher gas loads. |
| 2" (54mm) Gas Solenoid Valve | Large-bore valve for high-demand kitchens and plant rooms. |
| Flanged Gas Solenoid Valve (DN50–DN150) | Flanged valves for large-bore commercial and industrial gas supplies. |
Supplied, installed and commissioned
Every gas solenoid valve we fit is installed by Gas Safe registered commercial catering engineers and commissioned to BS 6173 and IGEM/UP/19. Commissioning includes failing each fan in turn, testing the emergency stop, confirming the gas solenoid valve closes, and recording the results.
You receive a written commissioning record, and the system can be included in your annual CP42 commercial gas safety certificate inspection.
Parts carried in stock
- Replacement gas interlock systems
- Gas solenoid valves in common sizes
- Air pressure switches
- Quick release gas catering hoses
- Super universal thermocouples
Repair, servicing and replacement
If your system stops resetting, keeps tripping or the gas will not come on, our engineers diagnose the fault on site. Most faults are a fan proving problem, a failed valve coil, an open emergency stop circuit or wiring disturbed during other work.
Annual servicing tests every safety function and is usually combined with the CP42 inspection to minimise disruption.
Regulations
BS 6173 requires gas supplies to commercial catering appliances to be interlocked with mechanical ventilation so appliances cannot operate without it. IGEM/UP/19 covers the design and application of interlock devices and CO₂ monitoring. The Gas Safety (Installation and Use) Regulations 1998 require installations to be maintained in a safe condition.
From our engineers' vans
Photos from real jobs — the equipment described on this page, installed and serviced by our engineers.



Frequently asked questions
Which valve does a kitchen interlock use?
A normally closed valve, usually 230V and 28mm on a typical restaurant.
Related guides
Normally Closed Gas Solenoid Valve
Closes when power is lost — the fail-safe valve used on gas interlocks.
Normally Open Gas Solenoid Valve
Stays open without power and closes when energised — used in specific shut-off schemes.
Manual Reset Gas Solenoid Valve
Must be reset by hand after closing, so gas cannot come back on by itself.
240V (230V) Gas Solenoid Valve
Mains-voltage coil — the most common coil on UK kitchen interlocks.
22mm (¾") Gas Solenoid Valve
For smaller kitchens and takeaways with a modest total gas load.
28mm (1") Gas Solenoid Valve
The most common commercial kitchen valve size.
35mm (1¼") Gas Solenoid Valve
For larger kitchens with higher gas loads.
2" (54mm) Gas Solenoid Valve
Large-bore valve for high-demand kitchens and plant rooms.
Flanged Gas Solenoid Valve (DN50–DN150)
Flanged valves for large-bore commercial and industrial gas supplies.
Parts in stock — ready to fit
Held in UK stock and carried on our vans, so most jobs are fixed in one visit.
Replacement gas interlock systems
Complete panels & kits ready to fit
In stock today
Air pressure switches
Fan & gas proving pressure switches
In stock today
Gas solenoid valves
Normally closed safety shut-off valves
In stock today
Quick release gas catering hoses
Commercial ranges, bays & mobile catering
In stock today
Super universal thermocouples
Fits most commercial gas appliances
In stock today
Need a part fitted?
Same-day engineer dispatch with these parts on the van.
Gas Safe Registered
Commercial catering & plant
24/7 UK Response
Same-day emergency dispatch
Vetted Engineers
DBS checked for schools & care
Transparent Pricing