Detection
Cellar Room Gas Detection
Cellars are low, enclosed and often unoccupied, which is exactly where escaping gas collects. Most cellar detection protects against carbon dioxide from beer gas and drinks dispense; basements with gas meters or boilers also need natural gas or carbon monoxide detection.
- CO₂ sensors mounted low, where heavy gas collects
- Warning sounder and beacon at the cellar entrance
- Annual calibration and test record
Quick answer
Cellar gas detection protects staff from carbon dioxide leaking from beer and drinks dispense gas, and from natural gas or carbon monoxide where a meter or boiler is in the basement. CO₂ sensors are fitted low, methane sensors high, with a warning beacon at the cellar entrance and annual calibration.
- Main risk
- CO₂ from dispense gas
- CO₂ limits
- 0.5% over 8 hours, 1.5% over 15 minutes
- Sensor height
- CO₂ low, natural gas high
- Service
- Annual calibration
- How to book
- Call 020 8935 5572 or book online, 24/7
What is a cellar room gas detection system?
A cellar room gas detection system is a fixed set of gas sensors wired to a control panel that watches the air in a cellar around the clock. When gas builds up, it warns staff with a sounder and a beacon at the cellar door before anyone goes down the steps, and it can shut off the gas supply automatically.
- CO₂ sensor heads at low level near cylinders, tanks and the dispense equipment
- Natural gas (methane) sensor at high level where a gas meter, pipework or boiler is in the cellar
- Carbon monoxide sensor at breathing height where a boiler or water heater is fitted
- Control panel with alarm relays, usually outside the cellar or at the top of the steps
- Repeater display, sounder and flashing beacon at the cellar entrance
- Optional link to a gas solenoid valve, the fire alarm or the building management system
What gases are found in a cellar?
The main risk in a pub or restaurant cellar is carbon dioxide. CO₂ cylinders and bulk tanks supply beer, cider and soft drinks dispense, and a leaking regulator, coupler or line can fill a small cellar quickly. CO₂ is heavier than air, colourless and has no warning smell at dangerous levels.
Many cellars and basements also house the gas meter, the incoming gas service or a boiler. Natural gas (methane) is lighter than air, so it gathers at ceiling level rather than at the floor. Where a boiler or water heater is fitted, carbon monoxide is a third risk.
Where cellar gas detectors are fitted
A repeater display or warning beacon is fitted at the top of the cellar steps so staff can see the status before they go down. Sounders are placed inside and outside the cellar.
| Gas | Behaviour | Sensor position |
|---|---|---|
| Carbon dioxide (CO₂) | Heavier than air, pools at floor level | Low level, near cylinders, tanks and dispense equipment |
| Natural gas (methane) | Lighter than air, rises | High level, above the meter and gas pipework |
| Carbon monoxide (CO) | Mixes with room air | Breathing height near the boiler or heater |
CO₂ alarm levels
UK workplace exposure limits for carbon dioxide are 5,000 ppm (0.5%) averaged over eight hours and 15,000 ppm (1.5%) over 15 minutes. Cellar CO₂ monitors are usually set with a first alarm at or below the long-term limit and a second, evacuation alarm at or below the short-term limit.
On alarm, staff should not enter the cellar, should ventilate it from outside where it is safe to do so, and should call the gas supplier or an engineer to find the leak.
Linking detection to the gas supply
Where a cellar contains a gas meter, boiler or gas pipework, a natural gas detector can be wired to a normally closed gas solenoid valve so the supply is shut off automatically on high alarm. The valve then needs a manual reset, so someone must check the cause before gas is restored.
In kitchens, CO₂ monitoring can also be linked to the gas interlock so the cooking gas is shut off if the air quality falls too far. That is a separate system from cellar CO₂ detection for drinks dispense, although both can share one control panel.
Installation and servicing
- Survey of the cellar layout, gas sources and ventilation
- Sensors, control panel, sounders and entrance beacon fitted and wired
- Commissioning with test gas to prove each alarm level
- Annual service with calibration certificate, or sooner after any alarm
- Sensor heads replaced at the end of their rated life
What to do when the cellar gas alarm goes off
- Do not go down into the cellar, and stop anyone else from entering
- If someone is already in the cellar, call them out; never go in after a collapsed person, call 999
- Turn off the CO₂ cylinders or bulk tank at the main valve if it is outside the cellar and safe to reach
- Open the cellar doors or hatches from outside to let the gas clear, if it is safe to do so
- For a natural gas alarm, call the National Gas Emergency Service on 0800 111 999
- Only re-enter once the panel shows normal readings, then call an engineer to find the leak
Choosing the right cellar CO₂ detector
Cellar CO₂ detectors use infrared (NDIR) sensors, which measure carbon dioxide directly and are not poisoned by cleaning chemicals. A domestic carbon monoxide alarm does not detect carbon dioxide at all, so it gives no protection against a beer gas leak.
Small cellars with one dispense area usually need a single CO₂ sensor and a door beacon. Larger cellars, cellars split into rooms, or cellars with a bulk CO₂ tank need more sensors so there is one close to each place gas could leak.
Cellar gas detection for different venues
| Venue | Main gas risks | Typical setup |
|---|---|---|
| Pub or bar cellar | CO₂ from beer and cider dispense | One or two low-level CO₂ sensors, door beacon and sounder |
| Restaurant or hotel basement | CO₂ from drinks dispense, natural gas from the meter | CO₂ low, methane high, shared panel |
| Cellar with a gas boiler | Natural gas and carbon monoxide | Methane high, CO at breathing height, gas shut-off valve |
| Basement kitchen | Natural gas, CO₂ from cooking | Methane detection linked to the kitchen gas interlock |
| Food and drink production | CO₂ from fermentation or carbonation | Several CO₂ sensors and ventilation boost on alarm |
What affects the cost of cellar gas detection
We give a fixed written price after a short survey or a call with photos of the cellar.
- How many gases need monitoring: CO₂ only, or CO₂ with natural gas and CO
- The number of sensors needed for the cellar's size and layout
- Cable runs between the cellar, the panel and the entrance beacon
- Whether the system shuts off the gas or links to the fire alarm or building management system
Who needs cellar gas detection?
Pubs, bars, restaurants, hotels, clubs and venues with drinks dispense gas in a cellar or enclosed room should have CO₂ detection. Basement kitchens and cellars containing a gas meter or boiler should be assessed for natural gas and carbon monoxide detection as part of the site's risk assessment.
Frequently asked questions
What is cellar room gas detection?
A fixed system of gas sensors and a control panel that monitors a cellar for carbon dioxide from drinks dispense, and natural gas or carbon monoxide where a meter or boiler is present, warning staff at the cellar door before they enter.
Where should a CO₂ detector be placed in a cellar?
Low down, within about 300 mm of the floor, near the gas cylinders, bulk tank and dispense equipment, because carbon dioxide is heavier than air and collects at floor level.
Is CO₂ detection required in a beer cellar?
Employers must control the risk from CO₂ under workplace health and safety law. In practice, fixed CO₂ detection with an alarm at the cellar entrance is the expected control wherever dispense gas is stored in a cellar or enclosed space.
How often should cellar gas detectors be calibrated?
At least once a year with a certified test gas, and after any alarm, sensor replacement or damage.
Can one panel cover CO₂ and natural gas?
Yes. A multi-channel panel can take CO₂, methane and CO sensors, each with its own alarm levels and outputs.
Will a carbon monoxide alarm detect a CO₂ leak in a cellar?
No. Carbon monoxide (CO) and carbon dioxide (CO₂) are different gases. A beer cellar needs a dedicated CO₂ detector with an infrared sensor.
Does a cellar with a gas boiler or meter need a gas detector?
It should be assessed. Cellars are enclosed and often unoccupied, so a natural gas detector at high level, and a CO detector near any boiler, are commonly fitted and can shut off the gas automatically.
How long does it take to fit cellar gas detection?
Most single-cellar systems are fitted, tested and commissioned in a day, usually outside trading hours.
Can the cellar gas alarm link to other systems?
Yes. The panel's relays can signal the fire alarm, building management system or a remote alert, and can close a gas solenoid valve.
Related guides
CO₂ Alarms
Carbon dioxide alarms for cellars and dispense areas.
Natural Gas Detectors
Gas leak alarms for kitchens and plant rooms.
Carbon Monoxide Detectors
Fixed CO monitoring for boiler and plant rooms.
Gas Detection Systems
Fixed gas leak detection for commercial premises.
Boiler Room Gas Detection
Gas and CO detection with automatic boiler isolation.
Gas Solenoid Valves
Normally closed automatic shut-off valves.
Parts in stock — ready to fit
Held in UK stock and carried on our vans, so most jobs are fixed in one visit.
Replacement gas interlock systems
Complete panels & kits ready to fit
In stock today
Air pressure switches
Fan & gas proving pressure switches
In stock today
Gas solenoid valves
Normally closed safety shut-off valves
In stock today
Quick release gas catering hoses
Commercial ranges, bays & mobile catering
In stock today
Super universal thermocouples
Fits most commercial gas appliances
In stock today
Need a part fitted?
Same-day engineer dispatch with these parts on the van.
Gas Safe Registered
Commercial catering & plant
24/7 UK Response
Same-day emergency dispatch
Vetted Engineers
DBS checked for schools & care
Transparent Pricing
Fixed callout, quoted parts