Sensors & controls
Gas Pressure Switches
A gas pressure switch opens or closes an electrical contact when the gas pressure crosses a set point. In commercial gas safety systems it proves there is enough pressure for safe burner operation and checks the pipework holds pressure during gas proving.
- Low gas pressure switches stop burners running on too little gas
- High pressure switches protect against governor failure
- Tested with a manometer against the set point
Quick answer
A gas pressure switch changes an electrical contact when gas pressure crosses a set point. Low gas pressure switches stop burners running on too little gas, high pressure switches lock out if pressure rises too far, and proving switches watch for pressure loss during gas proving. Each is tested with a manometer.
- Types
- Low, high, proving, differential air
- Tested with
- Manometer at the set point
- In stock
- Interlock panels, gas solenoid valves, air pressure switches
- How to book
- Call 020 8935 5572 or book online, 24/7
How a gas pressure switch works
Gas pressure acts on a diaphragm inside the switch. When the pressure passes the adjustable set point, the diaphragm moves a microswitch. The contact is wired into a burner controller, proving panel or interlock so that the system only allows gas when the pressure is right.
Types of gas pressure switch
| Type | Job | Where it is used |
|---|---|---|
| Low gas pressure switch | Stops the burner or locks out if supply pressure falls too low | Boiler and burner gas trains, large catering appliances |
| High gas pressure switch | Locks out if pressure rises too high, for example on governor failure | Boiler plant and process burners |
| Proving pressure switch | Watches for pressure loss during the proving test | Gas proving panels in kitchens and plant rooms |
| Differential air pressure switch | Proves a fan is moving air | Kitchen ventilation interlocks |
Gas pressure switches in gas proving systems
During gas proving, the panel briefly pressurises the downstream pipework and then watches a pressure switch. If the pressure holds for the test period, the main gas solenoid valve opens. If an appliance tap is open or a joint is leaking, the pressure falls, the switch changes state and the panel locks out.
Common gas pressure switch faults
- Set point drifted, causing nuisance lockouts
- Diaphragm damaged or sensing port blocked
- Microswitch contacts worn or wiring loose
- Wrong pressure range for the installation
- Low supply pressure from the meter or governor, which the switch is correctly reporting
Testing and replacement
A Gas Safe engineer connects a manometer at the test point, raises or lowers the pressure and checks the switch operates at its set point. Faulty switches are replaced with the correct pressure range, set, and the system is tightness-tested and recommissioned.
Frequently asked questions
What is a low gas pressure switch?
A switch that opens when the gas supply pressure falls below its set point, so the burner or proving panel locks out instead of running on too little gas.
What does a low gas pressure switch do?
It stops the burner or locks out the system if the gas supply pressure drops below a safe level, preventing poor combustion or flame failure.
What is the difference between a gas pressure switch and an air pressure switch?
A gas pressure switch monitors gas pressure in the pipework. An air pressure switch measures the pressure difference across a fan or duct to prove ventilation is running.
Can a gas pressure switch be adjusted?
Most have an adjustable set point, but it should only be set by a competent Gas Safe engineer using a manometer, and recorded at commissioning.
Related guides
Gas Proving Systems
Pressure proving before the gas is turned on.
Air Pressure Switches
Proving the extract fan is moving air.
Gas Safety Controls & Sensors
Airflow sensors, current monitors and E-stops.
Gas Solenoid Valves
Normally closed automatic shut-off valves.
Boiler Room Gas Detection
Gas and CO detection with automatic boiler isolation.
Gas Interlock Systems
How kitchen gas is linked to the extract and supply fans.
Parts in stock — ready to fit
Held in UK stock and carried on our vans, so most jobs are fixed in one visit.
Replacement gas interlock systems
Complete panels & kits ready to fit
In stock today
Air pressure switches
Fan & gas proving pressure switches
In stock today
Gas solenoid valves
Normally closed safety shut-off valves
In stock today
Quick release gas catering hoses
Commercial ranges, bays & mobile catering
In stock today
Super universal thermocouples
Fits most commercial gas appliances
In stock today
Need a part fitted?
Same-day engineer dispatch with these parts on the van.
Gas Safe Registered
Commercial catering & plant
24/7 UK Response
Same-day emergency dispatch
Vetted Engineers
DBS checked for schools & care
Transparent Pricing
Fixed callout, quoted parts