Sensors & controls

Gas Pressure Switches

A gas pressure switch opens or closes an electrical contact when the gas pressure crosses a set point. In commercial gas safety systems it proves there is enough pressure for safe burner operation and checks the pipework holds pressure during gas proving.

  • Low gas pressure switches stop burners running on too little gas
  • High pressure switches protect against governor failure
  • Tested with a manometer against the set point

Quick answer

A gas pressure switch changes an electrical contact when gas pressure crosses a set point. Low gas pressure switches stop burners running on too little gas, high pressure switches lock out if pressure rises too far, and proving switches watch for pressure loss during gas proving. Each is tested with a manometer.

Types
Low, high, proving, differential air
Tested with
Manometer at the set point
In stock
Interlock panels, gas solenoid valves, air pressure switches
How to book
Call 020 8935 5572 or book online, 24/7

How a gas pressure switch works

Gas pressure acts on a diaphragm inside the switch. When the pressure passes the adjustable set point, the diaphragm moves a microswitch. The contact is wired into a burner controller, proving panel or interlock so that the system only allows gas when the pressure is right.

Types of gas pressure switch

TypeJobWhere it is used
Low gas pressure switchStops the burner or locks out if supply pressure falls too lowBoiler and burner gas trains, large catering appliances
High gas pressure switchLocks out if pressure rises too high, for example on governor failureBoiler plant and process burners
Proving pressure switchWatches for pressure loss during the proving testGas proving panels in kitchens and plant rooms
Differential air pressure switchProves a fan is moving airKitchen ventilation interlocks

Gas pressure switches in gas proving systems

During gas proving, the panel briefly pressurises the downstream pipework and then watches a pressure switch. If the pressure holds for the test period, the main gas solenoid valve opens. If an appliance tap is open or a joint is leaking, the pressure falls, the switch changes state and the panel locks out.

Common gas pressure switch faults

  • Set point drifted, causing nuisance lockouts
  • Diaphragm damaged or sensing port blocked
  • Microswitch contacts worn or wiring loose
  • Wrong pressure range for the installation
  • Low supply pressure from the meter or governor, which the switch is correctly reporting

Testing and replacement

A Gas Safe engineer connects a manometer at the test point, raises or lowers the pressure and checks the switch operates at its set point. Faulty switches are replaced with the correct pressure range, set, and the system is tightness-tested and recommissioned.

Frequently asked questions

What is a low gas pressure switch?

A switch that opens when the gas supply pressure falls below its set point, so the burner or proving panel locks out instead of running on too little gas.

What does a low gas pressure switch do?

It stops the burner or locks out the system if the gas supply pressure drops below a safe level, preventing poor combustion or flame failure.

What is the difference between a gas pressure switch and an air pressure switch?

A gas pressure switch monitors gas pressure in the pipework. An air pressure switch measures the pressure difference across a fan or duct to prove ventilation is running.

Can a gas pressure switch be adjusted?

Most have an adjustable set point, but it should only be set by a competent Gas Safe engineer using a manometer, and recorded at commissioning.

Related guides

Parts in stock — ready to fit

Held in UK stock and carried on our vans, so most jobs are fixed in one visit.

  • Replacement gas interlock systems

    Complete panels & kits ready to fit

    In stock today

  • Air pressure switches

    Fan & gas proving pressure switches

    In stock today

  • Gas solenoid valves

    Normally closed safety shut-off valves

    In stock today

  • Quick release gas catering hoses

    Commercial ranges, bays & mobile catering

    In stock today

  • Super universal thermocouples

    Fits most commercial gas appliances

    In stock today

  • Need a part fitted?

    Same-day engineer dispatch with these parts on the van.

  • Gas Safe Registered

    Commercial catering & plant

  • 24/7 UK Response

    Same-day emergency dispatch

  • Vetted Engineers

    DBS checked for schools & care

  • Transparent Pricing

    Fixed callout, quoted parts

Call Us