Gas solenoid valve type
Normally Closed Gas Solenoid Valve
A normally closed (NC) gas solenoid valve is shut when de-energised and only opens when the coil is powered. If power fails, the fan fails or an emergency stop is pressed, the valve closes and gas stops. This is the standard valve for commercial kitchen interlocks.
- Fail-safe
- Sizes from 15mm to large flanged
- 230V and 24V coils
Quick answer
A normally closed (NC) gas solenoid valve is shut when de-energised and only opens when the coil is powered. If power fails, the fan fails or an emergency stop is pressed, the valve closes and gas stops. This is the standard valve for commercial kitchen interlocks.
- Standards
- BS 6173, IGEM/UP/19, IGEM/UP/11
- In stock
- Interlock panels, gas solenoid valves, air pressure switches
- How to book
- Call 020 8935 5572 or book online, 24/7
What is a normally closed gas solenoid valve?
A normally closed (NC) gas solenoid valve is shut when de-energised and only opens when the coil is powered. If power fails, the fan fails or an emergency stop is pressed, the valve closes and gas stops. This is the standard valve for commercial kitchen interlocks.
How it works
- The coil is powered by the interlock panel.
- Power lifts the plunger and opens the valve.
- Removing power lets the spring close it.
- Gas stays off until the panel is reset.
Typical uses
- All commercial kitchen interlocks
- Gas proving systems
- Detection shut-off
Features
- Fail-safe
- Sizes from 15mm to large flanged
- 230V and 24V coils
- In stock for fast replacement
What we check
- Valve closes on power loss
- Tightness when closed
- Coil resistance/temperature
- Correct flow direction
Choosing the right valve size
Valve size is chosen from the total gas rate of every appliance and the supply pipe size. An undersized valve causes pressure drop, poor flames and nuisance flame-failure lockouts. We measure working pressure at the furthest appliance with everything running.
| Size | Typical application |
|---|---|
| 22mm (¾") | Small cafés and takeaways |
| 28mm (1") | Most restaurants and pubs |
| 35mm (1¼") | Large restaurants and hotels |
| 2" / 54mm | Central kitchens, plant rooms |
| Flanged DN50–DN150 | Large plant and industrial supplies |
Supplied, installed and commissioned
Every normally closed gas solenoid valve we fit is installed by Gas Safe registered commercial catering engineers and commissioned to BS 6173 and IGEM/UP/19. Commissioning includes failing each fan in turn, testing the emergency stop, confirming the gas solenoid valve closes, and recording the results.
You receive a written commissioning record, and the system can be included in your annual CP42 commercial gas safety certificate inspection.
Parts carried in stock
- Replacement gas interlock systems
- Gas solenoid valves in common sizes
- Air pressure switches
- Quick release gas catering hoses
- Super universal thermocouples
Repair, servicing and replacement
If your system stops resetting, keeps tripping or the gas will not come on, our engineers diagnose the fault on site. Most faults are a fan proving problem, a failed valve coil, an open emergency stop circuit or wiring disturbed during other work.
Annual servicing tests every safety function and is usually combined with the CP42 inspection to minimise disruption.
Regulations
BS 6173 requires gas supplies to commercial catering appliances to be interlocked with mechanical ventilation so appliances cannot operate without it. IGEM/UP/19 covers the design and application of interlock devices and CO₂ monitoring. The Gas Safety (Installation and Use) Regulations 1998 require installations to be maintained in a safe condition.
Compare gas solenoid valve types
| Type | Summary |
|---|---|
| Normally Closed Gas Solenoid Valve | Closes when power is lost — the fail-safe valve used on gas interlocks. |
| Normally Open Gas Solenoid Valve | Stays open without power and closes when energised — used in specific shut-off schemes. |
| Manual Reset Gas Solenoid Valve | Must be reset by hand after closing, so gas cannot come back on by itself. |
| 240V (230V) Gas Solenoid Valve | Mains-voltage coil — the most common coil on UK kitchen interlocks. |
| 22mm (¾") Gas Solenoid Valve | For smaller kitchens and takeaways with a modest total gas load. |
| 28mm (1") Gas Solenoid Valve | The most common commercial kitchen valve size. |
| 35mm (1¼") Gas Solenoid Valve | For larger kitchens with higher gas loads. |
| 2" (54mm) Gas Solenoid Valve | Large-bore valve for high-demand kitchens and plant rooms. |
| Flanged Gas Solenoid Valve (DN50–DN150) | Flanged valves for large-bore commercial and industrial gas supplies. |
From our engineers' vans
Photos from real jobs — the equipment described on this page, installed and serviced by our engineers.


Frequently asked questions
Why normally closed?
Because it fails safe — any power loss shuts the gas off.
Is it normal for the coil to get hot?
Warm is normal; too hot to touch or buzzing suggests a failing coil or wrong voltage.
Related guides
Parts in stock — ready to fit
Held in UK stock and carried on our vans, so most jobs are fixed in one visit.
Replacement gas interlock systems
Complete panels & kits ready to fit
In stock today
Air pressure switches
Fan & gas proving pressure switches
In stock today
Gas solenoid valves
Normally closed safety shut-off valves
In stock today
Quick release gas catering hoses
Commercial ranges, bays & mobile catering
In stock today
Super universal thermocouples
Fits most commercial gas appliances
In stock today
Need a part fitted?
Same-day engineer dispatch with these parts on the van.
Gas Safe Registered
Commercial catering & plant
24/7 UK Response
Same-day emergency dispatch
Vetted Engineers
DBS checked for schools & care
Transparent Pricing
Fixed callout, quoted parts